Datasheet
PIC32MX3XX/4XX
DS61143H-page 170 © 2011 Microchip Technology Inc.
FIGURE 29-9: OC/PWM MODULE TIMING CHARACTERISTICS
OCFA/OCFB
OCx
OC20
OC15
Note: Refer to Figure 29-1 for load conditions.
OCx is tri-stated
TABLE 29-27: SIMPLE OC/PWM MODE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.3V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +105°C for V-Temp
Param
No.
Symbol Characteristics
(1)
Min Typical
(2)
Max Units Conditions
OC15 TFD Fault Input to PWM I/O Change — — 25 ns —
OC20 T
FLT Fault Input Pulse Width 50 — — ns —
Note 1: These parameters are characterized, but not tested in manufacturing.
2: Data in “Typical” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only