Datasheet

© 2011 Microchip Technology Inc. DS61143H-page 153
PIC32MX3XX/4XX
TABLE 29-5: DC CHARACTERISTICS: OPERATING CURRENT (IDD)
DC CHARACTERISTICS
Standard Operating Conditions: 2.3V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C TA +105°C for V-Temp
Param.
No.
Typical
(3)
Max. Units Conditions
Operating Current (I
DD)
(1,2)
DC20
8.5 13
mA Code executing from Flash
-40ºC,
+25ºC,
+85ºC
—4 MHz
9 15 +105ºC
DC20c 4.0 mA Code executing from SRAM
DC21 23.5 32 mA Code executing from Flash
——
20 MHz
(Note 4)
DC21c 16.4 mA Code executing from SRAM
DC22 48 61 mA Code executing from Flash
——
60 MHz
(Note 4)
DC22c 45 mA Code executing from SRAM
DC23
55 75
mA Code executing from Flash
-40ºC,
+25ºC,
+85ºC
2.3V
80 MHz
60 100 +105ºC
DC23c 55 mA Code executing from SRAM
DC24 100 µA -40°C
2.3V
LPRC (31 kHz)
(Note 4)
DC24a 130 µA +25°C
DC24b 670 µA +85°C
DC24c 850 µA +105ºC
DC25 94 µA -40°C
3.3V
DC25a 125 µA +25°C
DC25b 302 µA +85°C
DC25d 400 µA +105ºC
DC25c 71 µA Code executing from SRAM
DC26 110 µA -40°C
3.6V
DC26a 180 µA +25°C
DC26b 700 µA +85°C
DC26c 900 µA +105ºC
Note 1: A device’s I
DD supply current is mainly a function of the operating voltage and frequency. Other factors,
such as PBCLK (Peripheral Bus Clock) frequency, number of peripheral modules enabled, internal code
execution pattern, execution from program Flash memory vs. SRAM, I/O pin loading and switching rate,
oscillator type as well as temperature can have an impact on the current consumption.
2: The test conditions for I
DD measurements are as follows: Oscillator mode = EC+PLL with OSC1 driven by
external square wave from rail to rail and PBCLK divisor = 1:8. CPU, Program Flash and SRAM data
memory are operational, Program Flash memory Wait states = 7, program cache and prefetch are dis-
abled and SRAM data memory Wait states = 1. All peripheral modules are disabled (ON bit = 0). WDT
and FSCM are disabled. All I/O pins are configured as inputs and pulled to V
SS. MCLR = VDD.
3: Data in “Typical” column is at 3.3V, 25°C at specified operating frequency unless otherwise stated.
Parameters are for design guidance only and are not tested.
4: This parameter is characterized, but not tested in manufacturing.