Datasheet

© 2009-2011 Microchip Technology Inc. DS61156G-page 203
PIC32MX5XX/6XX/7XX
FIGURE 31-10: SPIx MODULE MASTER MODE (CKE = 0) TIMING CHARACTERISTICS
TABLE 31-28: SPIx MASTER MODE (CKE = 0) TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.3V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C
TA +105°C for V-Temp
Param.
No.
Symbol Characteristics
(1)
Min.
Typical
(2
)
Max. Units Conditions
SP10 TSCL
SCKx Output Low Time
(3)
TSCK/2 ns
SP11 T
SCH SCKx Output High Time
(3)
TSCK/2
——ns
SP20 T
SCF SCKx Output Fall Time
(4)
——ns
See parameter DO32
SP21 T
SCR SCKx Output Rise Time
(4)
——
ns
See parameter DO31
SP30 T
DOF SDOx Data Output Fall Time
(4)
——
ns
See parameter DO32
SP31 T
DOR SDOx Data Output Rise
Time
(4)
——
ns
See parameter DO31
SP35 T
SCH2DOV,
T
SCL2DOV
SDOx Data Output Valid after
SCKx Edge
——
15
ns V
DD > 2.7V
——
20
ns VDD < 2.7V
SP40 T
DIV2SCH,
T
DIV2SCL
Setup Time of SDIx Data Input
to SCKx Edge
10
——ns
SP41 T
SCH2DIL,
T
SCL2DIL
Hold Time of SDIx Data Input
to SCKx Edge
10
——ns
Note 1: These parameters are characterized, but not tested in manufacturing.
2: Data in “Typical” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance
only and are not tested.
3: The minimum clock period for SCKx is 40 ns. Therefore, the clock generated in Master mode must not
violate this specification.
4: Assumes 50 pF load on all SPIx pins.
SCKx
(CKP = 0)
SCKx
(CKP = 1)
SDOx
SDIx
SP11 SP10
SP40
SP41
SP21
SP20
SP35
SP20
SP21
MSb LSb
Bit 14 - - - - - -1
MSb In
LSb In
Bit 14 - - - -1
SP30
SP31
Note: Refer to Figure 31-1 for load conditions.