Information
DocID022152 Rev 4 101/185
STM32F405xx, STM32F407xx Electrical characteristics
Table 35. Main PLL characteristics
Symbol Parameter Conditions Min Typ Max Unit
f
PLL_IN
PLL input clock
(1)
0.95
(2)
12.10MHz
f
PLL_OUT
PLL multiplier output clock 24 - 168 MHz
f
PLL48_OUT
48 MHz PLL multiplier output
clock
-4875MHz
f
VCO_OUT
PLL VCO output 192 - 432 MHz
t
LOCK
PLL lock time
VCO freq = 192 MHz 75 - 200
µs
VCO freq = 432 MHz 100 - 300
Jitter
(3)
Cycle-to-cycle jitter
System clock
120 MHz
RMS - 25 -
ps
peak
to
peak
- ±150 -
Period Jitter
RMS - 15 -
peak
to
peak
- ±200 -
Main clock output (MCO) for
RMII Ethernet
Cycle to cycle at 50 MHz
on 1000 samples
-32 -
Main clock output (MCO) for MII
Ethernet
Cycle to cycle at 25 MHz
on 1000 samples
-40 -
Bit Time CAN jitter
Cycle to cycle at 1 MHz
on 1000 samples
- 330 -
I
DD(PLL)
(4)
PLL power consumption on VDD
VCO freq = 192 MHz
VCO freq = 432 MHz
0.15
0.45
-
0.40
0.75
mA
I
DDA(PLL)
(4)
PLL power consumption on
VDDA
VCO freq = 192 MHz
VCO freq = 432 MHz
0.30
0.55
-
0.40
0.85
mA
1. Take care of using the appropriate division factor M to obtain the specified PLL input clock values. The M factor is shared
between PLL and PLLI2S.
2. Guaranteed by design, not tested in production.
3. The use of 2 PLLs in parallel could degraded the Jitter up to +30%.
4. Based on characterization, not tested in production.
Table 36. PLLI2S (audio PLL) characteristics
Symbol Parameter Conditions Min Typ Max Unit
f
PLLI2S_IN
PLLI2S input clock
(1)
0.95
(2)
12.10MHz
f
PLLI2S_OUT
PLLI2S multiplier output clock - - 216 MHz
f
VCO_OUT
PLLI2S VCO output 192 - 432 MHz
t
LOCK
PLLI2S lock time
VCO freq = 192 MHz 75 - 200
µs
VCO freq = 432 MHz 100 - 300