STM32F20xxx Electrical characteristics
177
6.3.6 Supply current characteristics
The current consumption is a function of several parameters and factors such as the
operating voltage, ambient temperature, I/O pin loading, device software configuration,
operating frequencies, I/O pin switching rate, program location in memory and executed
binary code.
The current consumption is measured as described in Figure 20: Current consumption
measurement scheme.
All Run mode current consumption measurements given in this section are performed using
CoreMark code.
V
BOR2
Brownout level 2
threshold
Falling edge 2.44 2.50 2.56 V
Rising edge 2.53 2.59 2.63 V
V
BOR3
Brownout level 3
threshold
Falling edge 2.75 2.83 2.88 V
Rising edge 2.85 2.92 2.97
V
BORhyst
(1)
BOR hysteresis - 100 - mV
T
RSTTEMPO
(1)(2)
Reset temporization 0.5 1.5 3.0 ms
I
RUSH
(1)
InRush current on
voltage regulator
power-on (POR or
wakeup from Standby)
- 160 200 mA
E
RUSH
(1)
InRush energy on
voltage regulator
power-on (POR or
wakeup from Standby)
V
DD
= 1.8 V, T
A
= 105 °C,
I
RUSH
= 171 mA for 31 µs
--5.4µC
1. Guaranteed by design, not tested in production.
2. The reset temporization is measured from the power-on (POR reset or wakeup from V
BAT
) to the instant
when first instruction is read by the user application code.
Table 19. Embedded reset and power control block characteristics (continued)
Symbol Parameter Conditions Min Typ
Max Unit