Operator`s manual

5
4.0 Installation
The Lemur series printer was designed to be mounted either on a desktop or shelf (horizontal model) or
vertically in a counter top (see
Appendix B for installation of vertical printers).
Prior to site preparation and installation, the printer should be powered up and run in the self-test mode.
! Lay the printer flat on a counter top. On a Lemur-S model printer you will need to remove the side
cover.
! Attach the AC cord and interface cable into the proper connectors.
! Install ticket hopper (if applicable) to catch the tickets. Lemur printer without a cutter won’t have a ticket
hopper.
! Turn power on. The LCD will display PAPER OUT and the red Check Paper led will be illuminated.
You will hear the cutter motor cycle if the printer contains a cutter.
! Begin loading tickets through the entrance slot with a smooth motion until the printer automatically
positions the ticket. See section
5.0 Ticket Load Procedure.
NOTE: You want to make sure that the black timing mark is in the correct location before loading the tickets
into the paper path. See
www.bocasystems.com/tickets_specs.html for black mark layout specs.
! After the ticket is automatically positioned (the green READY led will be illuminated), press the TEST
button located on the control panel to print a test ticket. The next page shows sample self test ticket
printouts.
! Verify that the printer properly works with your system by issuing a ticket through your computer
system. You may also use out customer based program to test the printer independently of your
ticketing system (see
Appendix E)
You may now install the printer in its permanent location. Adequate room should be provided behind the
printer for the smooth feeding of ticket stock. Please do not prevent the ticket hopper (horizontal models) from
operating by touching tickets during the printing cycle.