Full Product Manual

23
PROGRAMMING REMOTES
The opener is supplied with two three-button remote controls (the second and third buttons can be used to
control an additional opener or gate if it contains a compatible receiver). Additional single and multi-button
remote controls can be purchased. The short wire on the back of the opener serves as an antenna for the
remote controls. Do not cut off the wire.
RED LED
LEARN BUTTON
Lights Flash
RED LED
Flash
1 2
Press and release the opener’s LEARN BUTTON.
Note: Pressing longer than 1 second will erase all
programming. The opener should BEEP and the LIGHT
should BLINK once. The RED LED will remain lit in
Learn Mode for 15 seconds.
Send a signal from the desired button on the
remote. The opener’s light and the red LED will
ash once if a remote was added.
Repeat Steps 1 & 2 for any additional remote controls or buttons.
TESTING THE REMOTE
Before testing the remote control, straighten out the opener’s antenna wire so it points up.
Stand clear of the door, press the remote control’s button and verify that the opener starts. PRESS THE
REMOTE CONTROL’S BUTTON AGAIN TO STOP THE DOOR MID-TRAVEL.
DELETING A REMOTE FROM THE GARAGE DOOR OPENER
If a remote is already programmed to the opener and you want to delete it, follow the same procedure as
PROGRAMMING REMOTES above. The opener will recognize the remote and delete it from memory. The
RED LED and LIGHT will blink 4 times to show the REMOTE was successfully deleted.
SAFETY REVERSAL SYSTEM TEST
The opener determines that there is an obstruction if a
higher than expected amount of force is detected during
a door cycle. If an obstruction is encountered during a
closing cycle, the opener and door will stop then fully
open. If an obstruction is encountered during an opening
cycle, the opener and door will stop.
1. With the door in the open position lay a 2”x4” board
at on the  oor where it will be struck by the center of
the door as it closes.
2. Activate the garage door opener using the wall station.
3. Verify that the door reverses when it strikes the board.
The door must reverse within two seconds after
striking the board.
TEST WITH SMALL OBSTACLE
THE DOOR MUST REVERSE
WITHIN 2-SECONDS AFTER
IMPACT WITH A 2 x 4 BOARD
2 x 4 BOARD LAID FLAT
UNDER
CENTER OF DOOR
TESTING THE SAFETY REVERSAL SYSTEM
Always perform the Safety Reversal System Test after making any adjustments to the opener.
PERFORM THE SAFETY REVERSAL SYSTEM TEST MONTHLY!
WARNING