15
Photo beam wires
For non-prewired installations, route the wires from the photo beams using insulated staples supplied, up the
wall above the door hardware, over to the center of the door, then along the ceiling, and back to the opener
head. Cut the wires about 6” longer than needed to reach the opener terminals. Strip back ½” of insulation
from the ends of the wires.
BEAM
COM
Beam wires
Twist one wire from each pair together, then
twist the other wire from each pair together.
Attach either twisted pair to the opener’s
BEAM terminal. Connect the other twisted
pair to the opener’s COM terminal.
Note: If an older system is being replaced,
use wire labels to mark connection types
prior to disconnecting wires.
IMPORTANT: Be careful to route the
photo beam wiring away from any
moving parts of the door or opener.
DO NOT route wires along the rail.
5
6
DO NOT
pierce wire
with staples
1/2”
3J