Instructions / Assembly

20 MM571W / MM572W Installation Instructions MM571W / MM572W Installation Instructions 21
DIP SWITCHES SETTINGS
Electrical Installation and Setup
Push/Pull-to-Open
On = Push
Off
= Pull
For changes to this switch to take effect, the unit must be reset or power cycled.
Stagger
For dual gate installations (MM572W),
OFF - Gates will open simultaneous, but close staggered.
ON - Gates will stagger while opening and closing for compatibility with gate
locks.
Warning
The WARNING DIP switch toggles a movement alarm ON or OFF.
Powering the System
Locate the ON/OFF switch on the bottom left of the control box.
Toggle the switch to the ON position.
The system will take approximately 20 seconds to power up indicated by an audible tone and LED D17 will ash.
10017426-CtrlBox_CoverOFF.ai
GRN
WHT
BAT+
AUTO
CLOSE
RESET
PULL
STAGGER
WARNING
BAT–
GRN
WHT
BRN
ORG
BRN
ORG
RED
BLU
RED
BLU
COM
COM
CYCL
SAFE
EXIT
SHDW
AUX
V+
AUX
V-
LOCK
V+
LOCK
V-
CLOSE
EDGE
OPEN
EDGE
PRIMARY
SECONDARY
LOCK AUX
SW1
SW2
PUSH
S2
S5
ON
12345
+
Step 4
MM572 Installation - For dual arm installation, drill through one of the Alternate Access slots to install the
Transformer or Solar power wires.
C
GRN
WHT
BAT+
AUTO
CLOSE
RESET
PULL
STAGGER
WARNING
BAT–
GRN
WHT
BRN
ORG
BRN
ORG
RED
BLK
RED
BLK
COM
COM
CYCL
SAFE
EXIT
SHDW
AUX
V+
AUX
V-
LOCK
V+
LOCK
V-
CLOSE
EDGE
OPEN
EDGE
PRIMARY
SECONDARY
LOCK AUX
SW1
SW2
PUSH
12345
+
TERM6
GRN
WHT
BAT+
BAT–
GRN
WHT
BRN
ORG
BRN
ORG
RED
BLK
RED
BLK
AUX
V+
AUX
V-
PRIMARY
SECONDARY
SW1
SW2
TERM6
Battery Power Access
From the other end of the low voltage wire,
strip 1/2” from both the RED and BLACK
wire.
On the transformer, connect RED wire to
the screw terminal marked + and BLACK
wire to the screw terminal marked -.
Plug the transformer into the selected
electrical outlet.
Note: Use of a surge protector is strongly
recommended.