Installation Guide
30 MM562 Installation Instructions 
Input Connections
  •  All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these 
inputs.
  •  All inputs are connected with respect to COMMON terminal.
  •  The status LED will blink once when any input is activated.
1 COM: Circuit common (reference for all 
logic input)
  •  Two (2) terminals to provide extra 
common connection point.
2 CYCLE/CLOSE:  (Typically for use with 
push button or hard-wired keypad)
  •  Each activation at this input will cycle 
the operation as follows:
 OPEN–STOP–CLOSE–STOP–OPEN 
3 SAFETY: (Typically for use with photo 
beam device, loop detector or other 
non-contact sensors)
  •  Activation of this input while the gate 
is closing will cause the gate to stop 
and return to the opened position.
  •  Activation of this input while the gate 
is opening has no eect (gate will 
continue to open).
  •  Activation of this input while gate is 
idle will prevent gate from closing.
4 EXIT/OPEN: (Typically for use with exit 
loop or wand)
  •  Activation of this input will open the 
gate if it’s not already at the open 
position
  •  Activation of this input while at open 
limit will restart the auto close time (if 
enabled).
5  SHADOW LOOP:  (Typically for use with loop detector)
  •  This input is only monitored when the gate is at the fully open position. At any other position, activation of 
this input has no eect on gate operation.
  •  Activation of this input while gate at the fully open position will prevent gate from closing.
6  CLOSE EDGE:  (Typically for use with safety edge device)
  •  Activation of this input while the gate is closing will cause the gate to stop and reverse direction for 
approximately 2 seconds.
  •  Activation of this input while the gate is opening has no eect (gate will continue to open).
  •  Activation of this input while gate is idle will prevent gate from closing.
7  OPEN EDGE: (Typically for use with safety edge device)
  •  Activation of this input while the gate is opening will cause the gate to stop and reverse direction for 
approximately 2 seconds.
  •  Activation of this input while the gate is closing has no eect (gate will continue to close).
  •  Activation of this input while gate is idle will prevent gate from opening. 
1
2
3
4
7
5
6
RECEIVER
ALM
GTO RCVR.
BLK
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
CONTROL INPUTS
CLOSE
EDGE