Installation Guide
26 MM562 Installation Instructions 
NOTE: The OPEN limit is when the opener is fully retracted and the gate is in the full open position. The open limit setting 
can only be adjusted by moving the gate bracket. To achieve the optimum closed position, you must adjust the CLOSED 
limit setting:
Step 1
Conrm that the power switch is in the ON position, and the gates are in the OPEN POSITIONS.
Step 2
Activate your openers by pressing the entry transmitter 
button. Your gates should now be moving from the fully 
open positions toward their closing position. Prepare to 
STOP gate that reaches the desired closed position rst 
by pressing the entry transmitter button again. This step 
may be repeated until desired close position is achieved.  
Once the desired CLOSED position has been achieved, 
proceed to step 3.
Step 3
Note which gate has reached the desired closed position 
(typically it's the Second gate), program the closed 
limit setting for that gate by pressing and holding the 
corresponding 'LEARN MAST LIMIT' or 'LEARN 2ND 
LIMIT' for 5 seconds.
Step 4
Press the transmitter button and allow the gates to 
return to the fully open position. YOUR FIRST 
GATE’S CLOSED POSITION LIMIT IS NOW 
PROGRAMMED.
Step 5
Activate your openers again by pressing the entry transmitter button. Your gates should now be moving from the fully open 
positions toward their closing position. The gate programmed in Steps 3 & 4 will stop at the spot you just programmed and 
the other gate will continue to close until you press the transmitter button again. The optimum CLOSED POSITION for the 
second gate is when it closes rmly, without excess tension, against the rst gate. This step may be repeated until desired 
close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 6.
Step 6
Repeat Steps 3 & 4 for the other gate that has not been set in step 3. 
Step 7
Press the transmitter button and allow the gates to return to the fully open position. BOTH YOUR MASTER AND SECOND 
GATE’S CLOSED POSITION LIMITS ARE NOW PROGRAMMED.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gates to close. If CLOSED positions are not correct or need to be changed, you 
will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-7 again.
CLEARING PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their fully opened 
positions, then press and hold the 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' button for 5 seconds. This will clear the 
memory for the closed limit positions. Follow Steps 1-7 again.
Setting the Closed Position Limits
for Pull to Open Applications
1 2 3 4
ON  DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT 
LEARN
SLV LIMIT 
S3
S4
S2
ART OFF
G OFF
 PULL
EN DLY.
 OFF
 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MINMAX
CLOSE TIME  STALL FORCE
Learn Master Limit
Button
Learn Slave Limit
Button
TURN CONTROL BOX ON