Instructions / Assembly
24 MM562 Installation Instructions 
Step 7
Plug the transformer into the electrical outlet.
(Use of a surge protector with the transformer is 
strongly recommended.)
HINT: Keep a few mothballs in the control box to 
discourage insects from entering it and damaging the 
control board.
NOTE: If transformer will be located outside be sure
to enclose in a weatherproof cover (not included).
Step 6
Strip 
1
/2" of insulation from the ends of the low voltage wire. Attach these stripped ends to the 
transformer terminals. 
A dab of household petroleum jelly on each terminal will help prevent corrosion.
Make sure the exposed wires do not touch each other!
SURGE PROTECTOR
Transformer
IMPORTANT: Never connect the transformer and a solar panel to the opener control board at the same 
time. It will damage the control board. 
If you are using the transformer included with the Mighty Mule Gate Opener to charge the opener battery, skip 
this section and go to "CONTROL BOARD SETTINGS" below. 
Strip 
3
/16" off the ends of the low voltage wire from the 
solar panel and twist tightly. Insert these ends to the 18 
VAC terminal block located on the control board (see 
illustration at right). The wires can be inserted into either 
terminal regardless of color. Be certain not to let the 
exposed wires touch each other!
Tighten set screws against exposed end of wires. 
NOTE: For multiple panels wire the panels in parallel as 
shown in this diagram.
RED 
RED 
BLACK 
BLACK 
attach BLACK (–) to SOLAR INPUT
attach RED(+) to SOLAR INPUT
Solar Panels connect in PARALLEL 
WHT
GRN
POWER
INPUT
LOCK
PWR
AUX
R LY
CONTROL
OUTPUTS
2ND OPERATOR
GTO 18VOLT
TRANSFORMER
OR SOLAR
GTO
LOCK
AUX
RED
BLACK
RED
BLACK
Low Voltage Wire
from Solar Panel
Solar Panel Connection