Step 3
Note which gate has reached the desired open position (typically it's the SECOND gate), program the open limit setting by pressing
and holding the corresponding 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' button for 5 seconds.
Step 4
Press the transmitter button and allow the gates to return to the closed position. The gate programmed in Step 3 has now learned its
limit.
Step 5
Activate your operators again by pressing the entry
transmitter button. Your gates should now be moving
from the fully close positions toward their opening
position. The gate programmed in Step 3 and 4
will stop at the spot you just programmed and the
other gate will continue to open until you press the
transmitter button again. This step may be repeated
until desired open position is achieved. Once the
desired OPEN position has been achieved, proceed
to step 6.
Step 6
Repeat steps 3 & 4 for gate that has not been
programmed yet.
Step 7
Press the transmitter button and allow the gates
to return to the closed position. BOTH YOUR
MASTER AND SECOND GATE’S OPEN
POSITION LIMITS ARE NOW PROGRAMMED.
TESTING YOUR OPEN LIMIT
SETTING:
Press your entry transmitter and allow your gates to
open. If OPEN positions are not correct or need to
be changed, you will need to CLEAR your OPEN LIMIT settings and follow steps one (1) to seven (7) again.
CLEARING THE PROGRAMMED OPEN LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their closed positions, then
press and hold the 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' button for 5 seconds. This will only clear the memory for the
open limit positions for the selected gate. Follow steps one (1) to seven (7) again.
1 2 3 4
ON DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
S2
ART OFF
G OFF
PULL
EN DLY.
OFF
OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MINMAX
CLOSE TIME STALL FORCE
Learn Master Limit
Button
Learn Slave Limit
Button
Setting the Open Position Limit
Step 1
Conrm that the power switch is in the ON position, and the gates are in the CLOSED POSITIONS.
Step 2
Activate your openers by pressing the entry transmitter button. Your gates should now be moving from the closed positions
toward their open position. Prepare to STOP gates by pressing the entry transmitter button again when the rst gate reaches
the desired open position. This step may be repeated until desired open position is achieved. Once the desired OPEN
position has been achieved, proceed to step 3.