Product Manual
MM562 Installation Instructions 31
RECEIVER
ALM
GTO RCVR.
WHT
BLU
BRN
ORG
RED
BLK
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
MASTER OPERATOR2ND OPERATOR
CONTROL INPUTS
CLOSE
EDGE
2 3 4 5 6 7
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
CYCLE
COM
LOCK
PWR
AUX
R LY
POWER
INPUT
CONTROL OUTPUTS
MASTER OPERATOR2ND OPERATOR
CONTROL INPUTS
GTO 18 VOLT
TRANSF. OR
SOLAR PANEL
1 2 3 4 5 6 7
1
2 3
4
5
6
7
Photo Beams (R4222)
Push Button Control (FM132)
Automatic Gate Lock (FM143)
According to
Application
Vehicle Sensor (FM138)
Refer to Vehicle Sensor
manual for additional
connections.
Edge Sensor
NOTE:
There may be additional connection options for
applications that are not illustrated here.
Refer to accessory manuals for details.
2
1
1
3
1
1
Digital Keypad (FM137)
4
1
2
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PRS
8
TUV
9
WXY
0
7
6
Connecting Other Auxiliary Devices (Sirens, Lights, etc.)
• These 2 terminals are normally open “dry-contact” (no voltage) relay ouput.
• Relay is closed when the gate is in motion; Relay is open when the gate is not in motion.
• These 2 terminals maximum rating is 24Vdc, 1 Amp.
Wiring Accessories
R LY
AUX