Product Manual

26 MM562 Installation Instructions
NOTE: The OPEN limit is when the opener is fully retracted and the gate is in the full open position. The open limit setting
can only be adjusted by moving the gate bracket. To achieve the optimum closed position, you must adjust the CLOSED
limit setting:
Step 1
Conrm that the power switch is in the ON position, and the gates are in the OPEN POSITIONS.
Step 2
Activate your openers by pressing the entry transmitter
button. Your gates should now be moving from the fully
open positions toward their closing position. Prepare to
STOP gate that reaches the desired closed position rst
by pressing the entry transmitter button again. This step
may be repeated until desired close position is achieved.
Once the desired CLOSED position has been achieved,
proceed to step 3.
Step 3
Note which gate has reached the desired closed position
(typically it's the Second gate), program the closed
limit setting for that gate by pressing and holding the
corresponding 'LEARN MAST LIMIT' or 'LEARN 2ND
LIMIT' for 5 seconds.
Step 4
Press the transmitter button and allow the gates to
return to the fully open position. YOUR FIRST
GATE’S CLOSED POSITION LIMIT IS NOW
PROGRAMMED.
Step 5
Activate your openers again by pressing the entry transmitter button. Your gates should now be moving from the fully open
positions toward their closing position. The gate programmed in Steps 3 & 4 will stop at the spot you just programmed and
the other gate will continue to close until you press the transmitter button again. The optimum CLOSED POSITION for the
second gate is when it closes rmly, without excess tension, against the rst gate. This step may be repeated until desired
close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 6.
Step 6
Repeat Steps 3 & 4 for the other gate that has not been set in step 3.
Step 7
Press the transmitter button and allow the gates to return to the fully open position. BOTH YOUR MASTER AND SECOND
GATE’S CLOSED POSITION LIMITS ARE NOW PROGRAMMED.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gates to close. If CLOSED positions are not correct or need to be changed, you
will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-7 again.
CLEARING PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their fully opened
positions, then press and hold the 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' button for 5 seconds. This will clear the
memory for the closed limit positions. Follow Steps 1-7 again.
Setting the Closed Position Limits
for Pull to Open Applications
1 2 3 4
ON DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
S2
ART OFF
G OFF
PULL
EN DLY.
OFF
OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MINMAX
CLOSE TIME STALL FORCE
Learn Master Limit
Button
Learn Slave Limit
Button
TURN CONTROL BOX ON