Instructions / Assembly

34 MM371W / MM372W Installation Instructions MM371W / MM372W Installation Instructions 35
Gate Operator Installation Checklist
1. The gate has been checked to make sure it is level and moves freely in both directions.
2. Potential pinch areas have been guarded so as to be inaccessible OR have sensing edges and/or photo
beam obstruction detection devices installed.
3. The installer has installed one or more contact or non-contact obstruction sensing devices, if required for
this installation.
4. If pedestrian trafc is expected, a separate pedestrian gate has been installed, a minimum of seven feet
from the gate system. All pedestrian trafc must use the pedestrian gate.
5. Warning signs have been installed on each side of the gate in highly visible locations. These signs must
remain at all times.
6. There are no controls installed on the gate operator, or within 10 feet of the gate.
7. The Dual Sense Technology™ feature has been properly adjusted to the minimum operational setting for
your application.
8. Reviewed and understand all of the operational functions, obstruction sensing devices, warning beeper
and reset, etc.
9. Review and understand the proper use of the operator’s manual disconnect feature. The manual
disconnect must never be used while the gate is in motion. The power switch must be turned off before
using the manual disconnect and disengaging the operator.
10. Reviewed all safety instructions, and keep the safety instructions and owner’s information sheets for
reference.
11. Review and understand the maintenance schedule for both the gate and the gate operator.
Appendix A
FM130 / FM130-SW Installation
For the FM130 / FM130-SW to function, the “Transmitter Module” must be programmed your
gate operator’s control board.
Before you begin:
Ensure the gate operator is in the OPEN position
Check to ensure the PUSH-PULL DIP setting is correct (see pages xiv & 21). If you
have to change this DIP setting, turn the unit OFF then ON to save setting.
Ensure the AUTOCLOSE is set to OFF.
Step 1: Choose a random dip switch setting on the Transmitter Module.
Step 2: On the gate operator control board, press and hold the (
, S3) button until LED2
illuminates and the buzzer sounds. Release the button.
Step 3: Insert both batteries into the transmitter module. The transmitter module will begin transmitting.
Step 4: Once Learned, LED2 will ash and the buzzer will sound indicating that the Transmitter Module has been learned.
Remove the AA batteries from the Transmitter Module, and proceed with the rest of the installation following the
accessory instructions.
Notes:
1. If you need to erase this device, repeat steps 2-4 above.
2. Erasing all transmitters on the gate operator control board will erase this device.
3. AUTOCLOSE may be turned back on after setup is complete.
FM136 Installation
As an alternative to the instructions provided with the FM136, the keypad can be learned to your gate operator
as an additional transmitter by following these instructions:
Step 1: Choose a random DIP setting on the keypad unit. Refer to the FM136 manual for the location of the
DIP switches.
Step 2: On the gate operator control board, press and hold the (return/enter, S3) button until LED2
illuminates and the buzzer sounds. Release the button.
Step 3: Enter your MASTER CODE on the FM136 keypad (1-2-3-4 is the default unless changed). Once
learned, LED2 will ash and the buzzer will sound on the gate operator control board. Proceed with
installation of the FM136 per the accessory instructions.
Notes:
1. If you need to erase this device, repeat steps 2-3 above.
2. Erasing all transmitters on the gate operator control board will erase this device.
FM130 / FM130-SW
ACCESSORY INSTALLATION INSTRUCTIONS