Product Manual
Mighty Mule MM360 Installation Instructions 29
Input Connections
• All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these inputs.
• All inputs are connected with respect to COMMON terminal.
• The status LED will blink once when any input is
activated.
1 COMMON: Circuit common (reference for all logic
input)
2 CYCLE: (Typically for use with push button or
hard-wired keypad)
• Each activation at this input will cycle the
operation as follows:
OPEN–STOP–CLOSE–STOP–OPEN
3 EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is closing or
opening will cause the gate to stop and reverse
direction for approximately 2 seconds.
• Activation of this input while gate is idle will
prevent gate from opening or closing.
4 SAFETY: (Typically for use with photo beam
device, loop detector or other non-contact
sensors)
• Activation of this input while the gate is closing
will cause the gate to stop and return to the
opened position.
• Activation of this input while the gate is opening
has no effect (gate will continue to open).
• Activation of this input while gate is idle will
prevent gate from closing.
5 EXIT: (Typically for use with exit loop or wand)
• Activation of this input will open the gate if it’s not
already at the open position
• Activation of this input while at open limit will
restart the auto close time (if enabled) and hold
the gate open if the contact is maintained.
6/7 AUX/OUT: Multi-function output: refer to pages 30 and 31.
CHARGING
POWER
RCVR
GRN
BLK
RED
EXIT
SAFETY
EDGE
CYCLE
COMMON
LINK
AUX
OUT
SOLAR
INPUT
18VAC/
H L
1
2
3
4
5
7
6
CONNECTING ACCESSORIES
Before You Begin
Mighty Mule strongly recommends the use of additional obstruction detection devices however we do not endorse any
specific brand names. Only use products that are listed to be in compliance with any applicable UL safety standards and
national and regional codes.
PLEASE NOTE: Contact sensors, non-contact sensors, shadow loops, etc. are not included with the Mighty Mule. Refer to the
sensor manufacturer’s instructions for information about installing accessory devices.
Mighty Mule gate openers ONLY accepts accessory devices with normally open dry contact outputs.
WARNING
Make sure the operator power switch is turned OFF before connecting ANY device wiring to the
terminals of the controller. Unplugging the transformer does not turn power to the operator off.