Product Manual
Mighty Mule MM360 Installation Instructions 25
DIP Switches
DIP Switch #1 - Push/Pull-to-Open
If your gate opens into the property (Pull-to-Open)
the DIP Switch is set to OFF (factory). If your gate
opens out from the property (Push-to-Open) the
DIP Switch must be set to the ON position.
NOTE: if you have a Push-to-Open gate
application see Push-to-Open Instructions on
page 32.
DIP Switch #4 - Lock/Beacon
This DIP selects the mode of operation of the "AUX
OUT" terminal.
The OFF (factory setting) position is selected if
you are using an Automatic Gate Lock with your Mighty Mule Opener.
(Refer to page 30, AUX/OUT Accessory Connection)
Control Board Settings
1
ON
234
15
CHARGING
POWER
STATUS
RF
PULL-PUSH
MODE1
MODE2
LOCK/BEACON
OFF 120
MIN MAX
STALL FORCE
CLOSE TIME
SET
LIMIT
LEARN
REMOTE
AUX OUT
SOLAR
PANEL
18VAC
RCVR
GRN
BLK
RED
EXIT
SAFETY
EDGE
CYCLE
COMMON
LINK
1
ON
234
PULL-PUSH
MODE1
MODE2
LOCK/BEACON
CONTROL BOARD SETTINGS
Use the transmitter to check the range of the receiver before
permanently mounting it.
Consider the following when mounting the receiver:
• Standard receiver cable length is 10 feet (receivers with a longer
cable are available as special order items; call the GTO Sales
Department). NEVER splice receiver cable!
• DO NOT run cable in conduit containing ac wiring.
• The receiver range can vary from 50 to 100 feet depending upon
weather, topography, and external interference.
NOTE: Do not mount upside down.
MOUNTING THE RECEIVER
Receiver mounted
on piece of wood