Product Manual

14 MM260 Installation Instructions
Visual Feedback
Symptom
Diagnosis Check:
Power (green) ON AC or Solar Power
Present
Normal Operation
Power (green) OFF No AC or Solar Power Transformer:
Breaker or GFI
Power at AC outlet.
Output of Transformer.
Voltage on wire at 18 VAC Input
Solar:
Solar Panel Wires Reversed
• Weather
Solar Panel Placement
Output of Solar Panel
Voltage on wire at Solar Input
TROUBLESHOOTING GUIDE