Product Manual

MM260 Installation Instructions 11
1 CHGR: Power Input Terminals:
Input terminals for transformer or solar panel.
2 CHGR: Power Input Terminals:
Input terminals for transformer or solar panel.
3 COM:
Common/Negative terminal for accessory devices
and negative wire from solar panel(s).
4 SAFETY: (Typically for use with photo beam device,
loop detector or other non-contact sensors)
Activation of this input while the gate is closing, or at
a position other than fully open will cause the gate to
stop and return to the opened position.
Activation of this input while the gate is opening has
no effect. (gate will continue to open)
Activation of this input while the gate is open will prevent
gate from closing.
Activation of this input while at open limit will restart the
auto close time (if enabled).
5 EXIT: (Typically for use with exit loop or wand)
Activation of this input will open the gate if it’s not already
at the open position.
Activation of this input while at open limit will restart the
auto close time (if enabled).
6 CYCLE: (Typically for use with doorbell button or hardwired
keypad)
Each activation at this input will cycle the operation
as follows:
…. OPEN STOP CLOSE STOP OPEN
7 EDGE: (Typically for use with contact edge sensor)
Activation of this input while gate is moving will cause it to
reverse direction for 2 seconds.
Activation of this input while idle will prevent gate from running.
8 COM:
Common/Negative terminal for accessory devices.
9 LOCK +: Positive terminal to connect GTO electro-mechanical lock. (FM143)
10 LOCK - : Negative terminal to connect GTO electro-mechanical lock. (FM143)
4
7
5
6
8
POWER
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
1
2
3
9
10
NOTE:
All accessory inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources
to these inputs.
All accessory inputs are connected with respect to COMMON terminal.
LOCK OUTPUTS
CHARGE POWER
INPUTS
ACCESSORY INPUTS
CONTROL BOARD CONNECTIONS