Product Manual A
18 MM-LPS13 Installation Manual
rev 05.14.13
CONNECTING SAFETY DEVICES
Make sure the control box power switch is OFF before connecting safety device wiring to
the terminal blocks.
Insert the safety device wires into the CLS EDG terminal (located on the terminal block) for the
gate closing mode. Connect the COMMON wire on the safety devices to the GRN terminal.
Connect the safety device wires for the gate opening mode to the OPN EDG terminal in the
same manner.
ON
SECOND OPERATOR FIRST OPERATOR POWER IN ALARM ACCESSORY RCVR
SEQ1
SEQ2
LEARN
18VAC SOLAR
~ ~ – +
RED
BLK
ORG
BLU
GRN
CLS EDG
OPN EDG
RED
BLK
BLU
ORG
ORG
BLU
WHT
GRN
GRN
CLS EDG
OPN EDG
R B G
Power Cable
Wire from Close Safety Edge
or Photo Beam
Wire from Open
Safety Edge or Photo Beam
Common
wire
Common wire to
GRN Terminal
The MM-LPS13 series operators are equipped with built-in obstruction detection. These operators are
designed to stop and reverse the gate for 2 seconds when it comes in contact with an obstruction.
Safety edges or photo beams MUST be installed on the gate.
Refer to the sensor manufacturer’s instructions for information about installing these devices on a
vehicular gate.
Power connections to
safety devices not shown.