Installation manual

22
Your Mighty Mule 250 has two Limit Settings
1) OPEN Limit setting: (Gate in the OPEN POSITION / FACTORY SET &
NOT ADJUSTABLE)
The open limit setting is the fully open position.
2) CLOSED Limit setting:
The CLOSED Limit setting (gate in the CLOSED POSITION)
To achieve optimum closed position, you are required to complete the
following FOUR STEPS:
Step 1
Confirm that the power switch in the ON position, the gate is
in the OPEN POSITION and the operator is mounted upside-
down with “SET CLOSE LIMIT" program button is visible
on the control board.
Step 2
Activate your opener by pressing the entry transmitter. Your
gate should now be moving from the fully open position
toward the closing position. Prepare to STOP gate when it
reaches the desired closed position by pressing the entry transmitter again. The optimum CLOSED POSITION is
when the gate closes firmly, without excess tension, against the gate post. The motor should run for one-half
second after the gate closes against the gate post. This step may be repeated until desired close position is
achieved. If this step requires you to cycle the opener more than 8-10 times, please allow the battery to recharge at
least 1 hour before trying again. Once the desired CLOSE position has been achieved, proceed to step 3.
Step 3
With your gate firmly closed. Program the closed limit setting by
PRESSING & HOLDING the “SET CLOSE LIMIT" button on
the control board for 5 seconds.
Step 4
Press the transmitter button and allow the gate to return to the
fully open position. YOUR CLOSED POSITION LIMIT IS NOW
PROGRAMMED.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gate to close. If CLOSED position is not correct or needs to be changed you
will need to CLEAR your CLOSED LIMIT setting and follow steps 1-4 again.
CLEARING PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to its fully opened
position, then press and hold the "SET CLOSE LIMIT" button for 10 seconds. This will clear the memory for the closed
limit position. Follow steps 1-4 again.
Programming the Closed Limit Position
EDGE
RED
BLK
GREEN
SAFETY
CYCLE
RADIO
18 VAC
INPUT
LEARN
TRANSMITTER
SET
CLOSE
LIMIT
COMMON
RED LED
GREEN LED
WHITE LED
YELLOW LED
15 AMP
Set Close Limit Button
Fully Open Position
Fully Closed Position
Control Board
ON
O
F
F
®
E-Z GATE OPENER
250
U
L
3
2
5
S
E
R
I
E
S
Can Cause Injury or Death
MOVING GATE
L
I
S
T
E
D
®
U
S
Transformer MUST be plugged in before
proceeding with this next section.