35
The Gate CLOSES Then Opens Again on its Own:
1. Check the position of the mounting brackets and readjust if necessary.
2. Check the gate for binding or hinge damage.
3. Check the position of the stroke adjustment knob.
The Gate OPENS Then Closes Again on its Own:
1. Check the position of the mounting brackets and readjust if necessary.
2. Check the gate for binding or hinge damage.
3. Check the position of the stroke adjustment knob.
One Gate OPENS and the Second Gate Doesn't in a
DUAL Gate Application:
1. Check the DIP switches on the control board and be sure the SNGL/DUAL is set to DUAL.
2. Check the Opener Power Cable for proper connection.
3. Check the fuse.
The GTO, Inc. Technical Service Department is open
Monday – Thursday 7:30 A.M. – 5:30 P.M.
and Friday 8:00 A.M. – 12:00 P.M. (Eastern Time)
Fax (850) 575-8950 • Web site: www.gtoinc.com
E-Mail: techsupport@gtoinc.com
Telephone (800) 543-GATE
Telephone (850) 575-0176
VOLTAGE RANGE
If the Opener is Working
18 VAC Transformer _________________________18.0 to 22.0 VAC
5 W Solar panel (single) _______________________18.0 to 22.0 VDC 300 mA
measure voltage at panel and control box.
12 V Battery ________________________________12.0 to 13.5 VDC 7.0 Ah
Charging circuit _____________________________13.0 to 14.8 VDC