Connect Opener Power Cables
Step 1
Bring FIRST power cable into the control box through a strain relief slot,
leaving enough wire to reach the FIRST OPR. terminal block.
Insert the individual power cable wires into appropriate terminals
on the FIRST OPR. terminal block (white to WHT; green to GRN; red to
RED; black to BLK). Tighten the set screws.
Step 2
Pull the 36' second opener power cable through the PVC conduit and
secure in the driveway slot/trench (see pages 6 and 14).
Step 3
Insert the SECOND power cable into a strain relief slot. Bring power
cable into the control box through a strain relief slot, leaving enough
wire to reach the SECOND OPR. terminal block.
Insert the individual power cable wires into appropriate terminals
on the SECOND OPR. terminal block (white to WHT; green to GRN; red
to RED; black to BLK). Tighten the set screws.
Connect the Transformer (*Solar
Instructions on Page 21)
NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!
IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE:
• TheonlywireacceptableforusewithMightyMuleproductsis16gaugestranded,lowvoltage,directburialwire.
This particular gauge enables the transformer to provide an adequate charge through the control board to the
battery at distances up to 1000'.
• DONOTusetelephonewireorsolidcorewire.Unlikestrandedwire,thesetypesofwireareinadequateforuse
with your gate opener system.
• NEVERsplicewirestogether.Splicingpermitscorrosionandseriouslydegradesthewire'sabilitytocarryan
adequate current.
Step 1
Make sure the power switch is OFF.
Step 2
Select the electrical outlet where you will plug the transformer. Measure
the distance from this outlet to the control box following the path
where the wire will be laid. After you have measured how much wire is
needed, cut the wire to the appropriate length (up to 1000').
FIRST Opener
Power Cable
SECOND Opener
Power Cable
Strain Relief Slots
(Battery Wires Not Shown)
VAR5
VAR6
K1
PF1
K2
BATT +
BATT
K3
K4
VAR4
VAR3
VAR2
VAR1
MIN
MAX
OFF
JP1
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
GTO Inc. Tallahassee, FL
R4722
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR.FIRST OPR.
RED
BLK
14 VAC
OR
SOLAR
ON OFF
Correct
Wrong Wrong
Wire
Terminal
Block
Terminal
Block
Terminal
Block
Wire Wire
ON/OFF
Switch
ON/OFF