C-RB48-NG(LP) 4.2、Gas Supply and Burner Information The minimum supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and 10”L.P. Gas W.C. The external thread of product’s intake-tube is 3/4 inches.
Model #of burners and control method C-RB24-N G(LP) 2 pieces Independent control C-RB36-N G(LP) 3 pieces Independent control C-RB48-N G(LP) 4 pieces Independent control Gas Species Intake-tube pressure (in.W.C.) Per BTU B.T.U./h Total BTU B.T.U./h Nozzle No.5. Transport and Storage In the process of transportation, handle carefully and keep upright to prevent damage to the product packing. Wrapped equipment should not be long-term open storage, and shall be placed in a well-ventilated and non-corrosive gases warehouse. When equipment needs temporary storage, rainproof measures should be taken. 6. Installation and Debugging Any erroneous installation, adjustment, refit, overhaul or maintenance may cause property damage or personal injury.
corners of the char broiler bottom, ensure sufficient space for ventilation; Adjustable stainless steel legs to make the equipment level, and get the same level with other series of the same stove; Please lift the equipment rather than drag if you need to move it; Open the grate, and take out the support under it, and reinstall grate after you make sure the thermal radiation plate is unmoved, and dispose the support; Supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and 10”L.P. Gas W.
6.2、Debugging It’s very important to debug the new stove. Through the comprehensive system test of equipment, we can ensure product’s function and safety performance. Discovering any potential problems before use (such as equipment’s placement, ventilation, operation, etc), can avoid costly losses. 7. Safety Notices and Precautions Warning! For your safety, do not place petrol and other flammables nearby. Please keep clean and free of flammables surroundings. (Read ANSI Z83.
we insist the operator take care when in contact with this piece of equipment; Always keep hands, hair and clothing away from heating source. Waiting until the unit cools down before you clean. Because the unit is too hot to handle after using. 8. Operating Instructions Before operating, make sure place the unit horizontally by adjusting bottom adjustable legs, and place the catch tray properly. The pilot light has been set at the factory. Each burner has a pilot light. 8.
After turning off the equipment, the main fire should be stop more than 5 minutes before next using. 8.4、Stove Operation Before using the stove for the first time, please use a mild detergent to wipe it clean. Do not use corrosive or abrasives detergent. Turn the burners on about 15-20 minutes before broiling for preheating, according to the cooking requirement to adjust the flame size. Notice: When first preheating, the furnace will smoke rise.
not get loose in the process of moving and translation. Reinstall control panel. Caution: Each burner damper has been adjusted before delivery (once air input), normal use without adjustment but only switching gas. Adjust only by authorized and licensed technicians. Fig.8 Fig.9 Fig.10 9.
Item Method Time Body Wipe it with a soft cloth and mild detergent daily Control panel Turn off the valves when not in use; Wipe panel and control valve knob with mild detergent. daily Caution: Wear insulated gloves when handling grates or radiants, in order to prevent possible burns! 1.Take out grates and radiants; 2.Clean up grease and other impurity on grates with a wire brush; 3.Clean grid slot with a scraper; Grates & Radiants 4. Grates coated with food grade lubricants. Problems Possible causes Problem solving Not lighting 1.Insufficient gas pressure in pipe 1.Contact the local gas supply dept. 2.Nozzle occlusion 2.Dredge nozzle 1.Insufficient gas pressure in pipe 1.Contact the local gas supply dept. 2.The main occlusion 2.Dredge nozzle Ignite the pilot light but not the main fire Close gas and heard a sound of fire Yellow flame and black smoke fire nozzle 3.Gas control valves have problems 3.Change gas control valves 4.The use of parts provided by other companies, our company has the right not to provide warranty service; Order replacement parts from authorized representatives and after-sale service agency. Provide the model number, serial number and description when you order components. Fig.
Matters Component No. 1 Dimensions Qty Code name 301110001 Adjustable steel leg (mm)/Model 4 21105001001 2 21105002001 Catch tray Remark 1 21105003001 φ41.5*100 C-RB24-NG(LP)\36NG(LP)\48-NG(LP) 507*620*26.5 C-RB24-NG(LP) 807*620*26.5 C-RB36-NG(LP) 1107*620*26.
2 11 12 13 14 15 301040006(NG) A18 nozzle (NG) 301040007(LP) A18 nozzle(LP) 301030001 21102001030 301170015 301060003 Pilot light valve-single unit Air input pipe Pilot light head stator Pilot light head 3 C-RB24-NG(LP) NG36 LP50 4 C-RB48-NG(LP) 2 C-RB24-NG(LP) 3 AP7-1 C-RB48-NG(LP) 2 C-RB24-NG(LP) 3 φ4.7*0.6 L=400 countertop C-RB48-NG(LP) 2 C-RB24-NG(LP) 3 C-RB36-NG(LP) 4 C-RB48-NG(LP) 2 C-RB24-NG(LP) 3 1 21205003001 A73007/TiPφ4.
21 301010007 22 23 U-type burner 301030014 pressure maintaining valve 301070001 24”countertop char broiler intake-tube 301070002 36”countertop char broiler intake-tube 301070003 48”countertop char broiler intake-tube 8 C-RB48-NG(LP) 2 C-RB24-NG(LP) 3 C-RB36-NG(LP) 4 C-RB48-NG(LP) 1 21205001002 24 21205002002 surround 4”-10” C-RB24-NG(LP)\36NG(LP)\48-NG(LP) Φ26-503*648 C-RB24-NG(LP) Φ26-803*648 C-RB36-NG(LP) Φ26-1113*648 C-RB48-NG(LP) 600*640*203 C-RB24-NG(LP) 900*640*203
1、Pressure maintaining valve connects with air intake, must be installed by authorized and licensed technicians, to assure interface tightness. 2、Screw the hex nut (Fig.12) before connect air intake, ensure gas mark (Fig.13) on the plastic core whether match with connected gas source, if not, then pull out the plastic core and change another head, insert it again. The same as exchanging gas source. 3、When exchange gas source, use the A18 orifice (Fig.14) in the accessories. Follow rules of 8.5. Fig.
life length of the products. Contact the dealer for assistance. In order to avoid confusion, please follow the format in figure 11 and table 4. Migali Industries, Trusted Since Inc. 1955 516 Lansdowne Ave Camden, NJ 08104 Service Call: 800.852.5292 Service Email: warranty@mgiali.