Technical information
Technical Information
98
G 600/G 800
A program can only be restarted after the fault has been addressed and the fault code has
been deleted.
The following faults are possible:
NTC sensor or its connections short- or open-circuited
Control module fault
Heater circuit open-circuited
6.8.4.4.2 Program Interruption and Intake/Drain LED Flashes
Program selection is possible.
The electronic has registered a fault during program operation. This can be checked via
Service Mode 2.
The following faults are possible:
Water intake or drainage
Flow meter B3/4 - Heater pressure switch B1/10
Overflow level switch B1/2
6.8.5 G 681, G 881 Novo Stella, G 886 Novo Stella Plus
(G 681/G 881 shown)
Programming Flow Chart
Enter Programming Mode
To access:
Program index
Water hardness settings
Extended drying 14 minutes
Extended water intake
Buzzer (EGPL 552 only)
Enter Service Mode 1
To access:
Manual step mode
Component test program
Enter Service Mode 2
To access:
Fault codes
Operating hours
Increased water temperature selection
Water softener (with/without)
Extended water intake
Interim rinses
Extended drying 45 minutes
Table 6-26: G 681, G 881 Novo Stella, G 886 Novo Stella Plus Programming Flow Chart
6.8.5.1 Programming Mode
1. To access the programming mode, close the door and turn the program
selector switch to Stop. Turn the dishwasher off.
2. Press and hold the Delay Start and Start buttons while turning the dishwasher
on. A blinking Salt light indicates successful accessing of the programming