Technical information

Technical Information
93
G 600/G 800
6.8.3.3.2 Deleting Stored Fault Codes
Access Programming Mode and turn the dishwasher off.
6.8.3.3.3 Program Index
1. Access Service Mode 2.
2. Turn the program selector switch to the 2 o’clock position. The Top solo light flashes.
3. Press the Top solo button once, then turn the program selector switch slowly clockwise
until the Top solo light lights up. The program selector switch position will determine the
corresponding program index, as shown in Table 6-18 below.
4. Turn the dishwasher off.
Program selector position Program index Electronic version
1 o’clock P0 EPLG 542/544
2 o’clock P1 For future modifications
3 o’clock P3 For future modifications
Table 6-18: G 811, G 851, G 851 Plus, G 856, G 856 Plus Program Indices
6.8.4 G 680, G 880
Programming Flow Chart
Enter Programming Mode
To access:
Water hardness
Drying Plus (EPLZ 501 only)
Temperature reduction (EPLZ 501 only)
Enter Service Mode 1
To access:
Switching step check
Test program
Enter Service Mode 2
To access:
Fault indication
Program index
Temperature increase
Softener
Flow meter
Dishwasher width setting
Increased water quantity (EPLZ 520 only)
Table 6-19: G 680, G 880 Programming Flow Chart
Note:
Electronics EPLZ 501 and EPLZ 520 differ from each other in housing, plug
configuration and software. The designation can be checked in Service Mode 2.
EPLZ 520 is marked with the program index “P3” or higher.
6.8.4.1 Programming Mode
1.
Switch the appliance off at the on/off switch, close the door and turn the program
selector switch to Stop.