Technical information

Technical Information
46
G 600/G 800
Component Part Activation
Circulation pump M6 Relay
Drain pump M8 Relay
Heater relay 1K/1 solenoid Thyristor
Power supply relay 1K/6 solenoid Via switch S2 (EWZ 548)
WaterProof System solenoid valves Thyristor
Reactivation solenoid valve Thyristor
Detergent dispenser Y51 solenoid Thyristor
Rinse aid dispenser Y50 solenoid Thyristor
Table 4-11: Activation of Components
4.25.1 Programming after Replacing the Electronic
In addition to intake duration and water softener settings, certain dishwasher
electronics need to be programmed for dishwasher width (45cm or 60cm).
For further details, refer to the model-specific programming and service mode
information.
4.25.2 Electronic Modes
The electronic modes are divided into 3 levels:
Programming mode
Service mode 1
Service mode 2
Programming mode is intended for user access. Service modes 1 and 2 are
designed to be accessed only by qualified service personnel.
Note:
While in service or programming mode, if the dishwasher is switched off or the door
is opened, the dishwasher will automatically exit the current mode and return to
normal operating mode.