28
G 600/G 800
Voltage
120VAC
Output power
1.5kW
Rated load
9.6kΩ
Table 4-3: Flow-Through Heater Electrical Data
4.5 Heater Circuit Operation
Figure 4-4: Heater Circuit
4.6 Pulsed Heating – Operation
In certain programs, heating may be operated at full power until a water temperature
of 77°F is reached, after which power is applied in pulses. This extends the heating
time and allows enzyme-containing detergents to develop their full cleaning potential.
Pulsed heating operates as follows:
1 minute heater element on.