Technical information
Technical Information
134
G 600/G 800
Programming Flow Chart
Enter Service Mode 2
To access:
Fault codes
Program index
Increased water temperature selection
Water softener (with/without)
Flow meter
Dishwasher width setting (18”/24”)
Table 6-81: G 879 Programming Flow Chart
Note:
The EPLG 501A and the EPLZ 530 differ from each other in the plug, the housing,
and the software. The EPLZ 530 is marked with the program index “P2” or higher.
6.8.15.1 Programming Mode
6.8.15.1.1 EPLG 501A (Program Index P1)
1. Open the dishwasher door and turn the dishwasher off.
2. Press and hold program buttons 1 and 3 while turning the dishwasher on. A blinking Salt
light indicates successful accessing of the Programming Mode.
3. Use program buttons 1 to 5 to select a function. See Table 6-82.
4. To save: Once options have been selected, press the Top solo button twice and turn off
the dishwasher.
Program button Function Options Program button light
1 Heated drying
On
2
Off
Off On
2 Water hardness setting
See Section
6.8.15.1.3
1
Flashing = 1 to 70 gpg
Off = 0 gpg
3 Temperature reduction
None
2
Off
Reduction of 41°F On
Table 6-82: G 879 Programming Functions for EPLG 501A
1
If no lights light up, the dishwasher is programmed to “without water softener”. To change to “with
water softener” follow the steps in Service Mode 2 (Section 6.8.15.3).
2
Factory setting
6.8.15.1.2 EPLZ 530 (Program Index P2 or Higher)
1. Open the dishwasher door and turn the dishwasher off.
2. Press and hold program buttons 1 and 3 while turning the dishwasher on. A blinking Salt
light indicates successful accessing of the Programming Mode.
3. Use program buttons 1 to 5 to select a function. See Table 6-83.
4. To save: Once options have been selected, press the Top solo button twice and turn off
the dishwasher.