6.8.13.3 Service Mode 2
Service Mode 2 is used to determine which upper electronic is in the appliance, to
change certain programmed functions and to access fault codes. The programmed
functions include increasing the water temperature, turning on or off the water
softener, adding an interim rinse, and setting the dishwasher width (18” or 24”).
1. To access Service Mode 2, open the dishwasher door and turn the dishwasher off.
2. Press and hold program buttons 2 and 3 while turning the dishwasher on.
Successful accessing of Service Mode 2 is indicated by flashing Salt and
Intake/Drain lights.
3. Illuminated program button lights will indicate the current program settings (see
Table 6-70).
4. The settings can be changed by using program buttons 1 to 5. To change the
settings, press the corresponding program button indicated in Table 6-70.
5. To save: Press the program button 6 twice.
Program button Function Options Program button light
1
Increase water
temperature
150°F Off
160°F On
2 Water softener
With
1
Off
Without On
3 2 interim rinses
With Off
Without On
4 Dishwasher width
24” Off
18” On
5
Program index - Off
Fault codes - On
Table 6-71: G 803, G 643, G 843, G 663, G 863 Service Mode 2 Functions
1
Factory setting
6.8.13.3.1 Accessing Fault Codes
1. Access Service Mode 2.
2. Press the flashing program button 5.
3. Press the flashing program button 1.
4. One of the program button lights (1 to 5) will light up, indicating a stored fault code of F0 -
F4. If none of the program buttons light, a fault code of F5 - F9 is stored. To display fault
codes F5 - F9, press program button 6 once. Program button 6 will light up along with
one of the other program buttons (1 to 5). See Table 6-72.
Program button 6
Program button
light
Fault code and description
Not pressed 1 F00 No error
Not pressed 2 F01 NTC or NTC connections open-circuited
Not pressed 3 F02 NTC or NTC connections short-circuited
Not pressed 4 F03
Electronic failure, selector switch
position not found
Not pressed 5 F04
Heating failure - heating circuit opened
or defective electrical component in
heating circuit
1
Pressed 1 F05
Water drainage failure, heater level
switch