Technical information

Technical Information
115
G 600/G 800
Program Function Options Program light status
Rinse & Hold Extended drying
1
Off Flashing
On Lit
Pots & Pans EGS
On Flashing
Off Lit
Table 6-51: G 892, G 832 Service Mode 2 Functions
1
Can only be set if “+14 min” is selected in programming mode. See Section 6.8.9.1.2.
6.8.10 G 694, G 894
Programming Flow Chart
Enter Programming Mode
To access:
Water hardness settings
Extended drying fan time (+14 minutes)
Enter Service Mode 1
To access:
Manual step mode
Component test program
Enter Service Mode 2
To access:
Error messages
Program index
Increased water temperature selection
Water softener (with/without)
Interim rinses
Extended water intake
Extended drying fan time (+ 45 minutes)
EGS
Table 6-52: G 694, G 894 Programming Flow Chart
6.8.10.1 Programming Mode
1. To access the programming mode, close the door and turn the dishwasher on.
The Start/Stop light must be blinking. If the Start/Stop light is not blinking, press
and hold the Start/Stop button for at least 3 seconds to exit the cycle. The
Start/Stop light should now be blinking.
2. Turn the dishwasher off.
3. Press and hold the Top solo and Start/Stop buttons while turning the
dishwasher on. Successful accessing of the programming mode is indicated by
a blinking Salt light.
4. The display will show the current water hardness setting. The “A” indicates
Aqua and the numbers indicate the hardness setting.
Note:
If the display is blank, the appliance has been programmed for “without softener”.
See Service Mode 2 (Section 6.8.10.3) to turn the water softener on or off.