Technical data
Remedy
A Run a timed warm air program.
Cause
Air path clogged.
Remedy
A Check the air paths and clean them.
Cause
Heater bank is not heating.
Remedy
A Check the heater element (R1) for short circuit and open circuit.
Cause
Heater relay (K1/1).
Remedy
A Check the heater relay (K1/1).
Cause
Temperature limiter (SOD, F2).
Remedy
A Check the temperature limiter (SOD, F2) for open circuit.
Cause
Defective residual moisture sensor (B3/1).
Residual moisture sensor (B3/1)-Check the sampler:
A Check the residual moisture sensor (B3/1) voltage circuit for high ohmic
(isolation) status, refer to Service mode summary, 090 4.3.