Technical data

3.5 LED Hand iron flashes
Symptom
The fault occurs in the operating mode: Program stop, cooling air phase, buzzer
sounds intermittently for 2 minutes.
Fault code F 3 or F 4 in the fault memory: NTC temperature sensor drying air
(1R30) short circuit or open circuit.
Cause
Temperature sensor heating/drying (2R30) open circuit (< 68 °F), evaluation only
af ter the heater has been run for at least 1 minute.
Remedy
A Check the lines and plugs of temperature sensor heating/drying (2R30) for
shor t circuit and open circuit.
A Temperature sensor heating/drying (2R30) characteristic curve, refer to 030
Table 3.
Cause
Heater bank is not heating. Unheated, the sensor is below the measuring
threshold of 68 °F.
Remedy
A Electric: Check the heater element (R1) for short circuit and open circuit.
Cause
Electric: Defective heater relay (K1/1).
Remedy
A Check the heater relay (K1/1).
Cause
Electric: Temperature limiter with manual reset (F1) has tripped.
Remedy
A Reset the temperature limiter (F1).
A Find the cause for the temperature limiter tripping, and rectify it.