3 Fault Repair
3.1 LED Anti-Crease/End lights up solid
Symptom
This fault occurs in the normal operating mode, only in residual moisture
programs.
Program stop, cooling air phase, intermittent buzzer tone.
Opening and then closing the door deletes this fault message.
Cause
The drum is empty, or loaded with a few laundry items only. The laundry is too
dr y.
The residual moisture sensor (B3/1) voltage circuit is high-ohmic, the residual
moisture sensor has no-load detection, this is not a technical fault.
No-load detection, refer to 030 2.1 No-load detection.
Remedy
A Correct the load, or switch to a timed program.
Cause
Defective residual moisture sensor (B3/1).
Check the residual moisture sensor (B3/1)
A Check the residual moisture sensor (B3/1) for low-ohmic (continuity) status,
refer to Service mode summary, 090 4.3.
Descriptive Technical Documentation
090-6 DTD no. 12-9800
This information should not be duplicated or passed on without Miele approval. All rights reserved. 05.12.2006, US_am