2.1.4 Temperature sensor heating/drying (2R30)
Temperature sensor heating/drying (2R30) at the reflective plate, under the back
service panel, NTC characteristic curve, refer to 030 Table 3.
2.1.5 Temperature limiter (1F1, 2F1)
Two 3/4 bi-metal temperature limiters (1F1, 2F1) with manual reset at the burner.
The bi-metal temperature limiter (1F1) at the burner exit serves to detect any
overheating of the burner due to insufficient air or air leakage.
The bi-metal temperature limiter (2F1) at the burner entrance serves to detect any
flame flashback.
Descriptive Technical Documentation
031-6 DTD no. 12-9800