Technical information
Technical Information
70
T1302, T1303, T1322, T1329ci, T1323c,
T1403 and T1405 Clothes Dryers
TEST STEP
Flashing
Rhythm Of
Drying LED
SERVICE
LEVEL
Flashing
Rhythm Of
Buzzer LED
SERVICE
FUNCTION
Long Short
Function Tested/Machine
Response
–
5
Residual moisture sensing circuit,
high resistance check.
Ensure the clip leads or the wires
used in the low resistance check
are removed; and no laundry is
present in the drum.
The appliance will operate for
about 30 seconds. When the
appliance stops observe the
Normal LED:
- On Steady: System OK.
- Flashing: System faulty.
–
6
Buzzer test.
Vented dryer: Constant tone.
Condenser dryer: Intermittent
tone.
–
7
LED display test.
Each individual segment of the
display and the LEDs flash
2
Refer to the Test
Step – Activation
and Navigation.
–
8
Heating relay 1 and 2 and drive.
Drum turns with reversing as
follows: 10 minutes counter
clockwise, 2.5second pause, 10
seconds clockwise, 2.5 second
pause, etc.
Heating 2 comes on after 1
second during counterclockwise
rotation.
Table 060-5: Service Mode (continued from Table 060-4) (continued on Table 060-6)