Operating instructions

INSTALLATION INSTRUCTIONS
Grounding and Electrical con-
nection
Grounding instructions
This appliance must be grounded.
In the event of a malfunction, ground-
ing will reduce the risk of electric shock
by providing a path of least resistance
for the electric current. This appliance
is equipped with a cord having an
equipment grounding conductor and a
grounding plug. The plug must be
plugged into an appropriate outlet that
is properly installed and grounded in
accordance with all local codes and or-
dinances.
Warning
Improper connection of the equip-
ment-grounding conductor can re-
sult in a risk of electric shock.
Check with a qualified electrician or
serviceman if you are in doubt as to
whether the appliance is properly
grounded.
Do not modify the plug provided
with the appliance; if it will not fit the
outlet, have the proper outlet in-
stalled by a qualified electrician.
Electrical connection
This installation should be done by an
experienced and qualified person, in
most cases a licensed electrician, in ac-
cordance with local codes and regula-
tions.
The dryer is supplied with a 5 ft long,
12/4 AWG cord and a NEMA 14-30 P plug.
It should be connected to a 120/240 V
(208 V), 15 A, 60 Hz AC power supply.
A 3 pole-4 wire grounding receptacle is
needed. (NEMA type 14-30 R).
EASY INSTALLATION KIT
If you do not have a dedicated 15 Amp
line for this appliance, but you have the
standard 3 or 4 wire, 240 V - 30 Amp
outlet, you can use the Easy Installa-
tion Kit, which allows you to use that
line to connect this appliance.
For more information on the electrical
connection and the Easy Installation
Kit please contact
the nearest Miele Service Depart-
ment.
INSTALLATION INSTRUCTIONS
19