Installation Guide
Table Of Contents
- Capa
- Índice
- Contents
- Installation and planning notes
- PWM 916
- Obsah
- Pokyny k instalaci a plánování
- PWM 916
- Tartalom
- Telepítési és tervezési útmutatók
- PWM 916
- İçindekiler
- Kurulum ve Planlama Talimatları
- PWM 916
- Índice
- Instruções de instalação e plano
- PWM 916
- Contents
en - PWM916
17
Technical data
Voltage versions and electrical data
3NAC400V, 50/60Hz, SD
Supply voltage 3N AC 400V 50/60Hz
Frequency 50/60 Hz
Required fuse rating (on site) 16 A
Power rating 2,3 kW
Connection cable, min. cross-section 1,5 mm²
Cable gland
3NAC400V, 50/60Hz, SI
Supply voltage 3N AC 400V 50/60Hz
Frequency 50/60 Hz
Required fuse rating (on site) 16 A
Power rating 2,3 kW
Connection cable, min. cross-section 1,5 mm²
Cable gland
Plumbing
Models with detergent drawer (DD)
Permitted flow pressure 1000 kPa
Maximum intake rate 47,5 l/min
Cold water connection
(to be provided on site, male thread according to DIN44991, flat seal)
3 x ½” with ¾” threaded union
Optional hard water connection, cold
(on-site external thread according to DIN44991, flat seal)
2 x ½” with ¾” threaded union (optional)
Hot water connection (≤70°C)
(on-site external thread according to DIN44991, flat seal)
1 x ½” with ¾” threaded union
Length of inlet hoses supplied 1,55 m
Drainage
Maximum drain water temperature 95 °C
Waste water connection (on machine) Plastic pipe HTDN 70
Drain (on site) ConnectionDN 70
Maximum drainage rate 200 l/min
Connection for equipotential bonding
Male thread M10
Toothed washers M10