Installation Plan Washing Machine PW 811 PW 814 PW 818 To prevent accidents and machine damage, read these instructions before installation or use. en-US M.-Nr.
Contents Installation and planning notes .......................................................................................... 4 Installation requirements ....................................................................................................... 4 Storage/Transportation.......................................................................................................... 4 General operating conditions ......................................................................................
Contents PW 814................................................................................................................................ Dimensions..................................................................................................................... Dimensions with Miele base (UG/UO)/weighting base (WI) ........................................... Installation ...................................................................................................................... PW 818...
Installation and planning notes Installation requirements The washing machine must be installed by Miele Service or by properly trained staff of an authorized dealer. This washing machine must be installed in accordance with all relevant regulations and standards. Local energy supplier regulations must also be observed. This washing machine must only be operated in a room that has sufficient ventilation and which is frost-free.
Installation and planning notes Installation This washing machine must be transported to its installation site using a suitable pallet jack. Remove the transport packaging. The washing machine must be set up on a level and firm surface with the minimum stated load bearing capacity (see "Technical data"). The floor load created by the washing machine is concentrated and transferred to the installation footprint via the machine feet.
Installation and planning notes Leveling the machine Align the washing machine vertically and horizontally using the ad- justable feet and a spirit level. The washing machine must stand perfectly level on all four feet to ensure safe and proper operation. Otherwise water and energy consumption will be increased and the machine could move. After aligning the machine tighten the lock nuts by turning them in a counterclockwise direction with a wrench. This will prevent the feet from moving.
Installation and planning notes Installation of steam-heated washing machines The steam connection must only be carried out by a registered installer. During connection please observe the installation instructions, the data plate on the washing machine, the wiring diagram, the installation diagram and the documentation supplied.
Installation and planning notes Heater bank infor- To avoid damage to the heater bank the following must be observed mation during commissioning: – In order to avoid unnecessary heat variations, ensure that heating is even. Do not allow sudden bursts of steam. – To prevent corrosion, preparation of the water supply is absolutely essential. In particular, when the machine is not in operation, it must be ensured that no air or CO2 can enter the steam system. – Protect the heater bank from aggressive gases.
Installation and planning notes Machine connections ① ② ③ ④⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ a Detergent dispenser (WEK) b Communication module slot The XKM RS232 communication module is available as an optional accessory.
Installation and planning notes Electrical connection The electrical connection must only be carried out by a qualified electrician who must ensure that all electrical work is carried out in accordance with applicable electrical regulations and standards. The washing machine must be connected to an electrical supply that complies with local and national regulations. Please also observe your insurance and energy supplier's regulations as well as any health and safety at work regulations.
Installation and planning notes If it is necessary to install a residual current device (RCD) in accordance with local regulations, a residual current device type B (sensitive to universal current) must be used. An existing type A residual current device, (RCD) must be exchanged for a type B RCD. If necessary, equipotential bonding with good galvanic contact must be guaranteed in compliance with all applicable local and national installation specifications.
Installation and planning notes Water connection The washing machine complies with current local and national safety regulations protecting the drinking water supply and can therefore be connected to the drinking water supply without a nonreturn valve. The machine is designed to operate with a supply pressure of between 14.5 psi (1 bar) and must not exceed 145 psi (10 bar). If it is highter than 145 psi (10 bar) a pressure reducing valve must be used.
Installation and planning notes Drain valve A motorized dump valve is used to drain the machine. A 2 ¾" angle connector can be used for draining the machine directly into the waste water system (without a siphon) or into an on-site gully (with odor trap). The dump valve can also be operated manually to allow the suds container to be emptied in the event of a power outage. A vented drainage system is vital for unimpeded drainage.
Installation and planning notes Dispenser pump connections Up to 12 dispenser pumps can be connected to the washing machine. Dispenser pump connections on the back of the machine Connections 1 and 2 are for viscous agents. These connectors are sealed and need to be drilled out before connection with a 5/16" (8 mm) drill bit. Make sure that you only drill through the first panel (I) as there is a deflecting panel (II) 3/8" (10 mm) behind it. Connections 3 to 12 are for liquid dispensing.
Installation and planning notes Optional accessories Only use genuine Miele spare parts and accessories with this machine. Using spare parts or accessories from other manufacturers will void the warranty, and Miele cannot accept liability. XKM RS232 communication module The serial interface RS-232 can be retrofitted to the washing machine via an XKM RS 232 (optional accessory available from Miele).
Technical drawings - dimensions in inches PW 811 Dimensions 53.2" 21" 19.4" 31.4" 32.6" 37" 18.6" 3.5" 0.9" 20.9" 29.1" 53.2" 16.3" 32.6" 53.2" 31.5" 31.4" 6.5" 31.5" 1" 3.4" 31.
Technical drawings - dimensions in inches Dimensions with Miele base (UG/UO)/weighting base (WI) 32.6" 19.4" 64.6" 64.7" 64.6" 21" 16.3" 31.5" 32.6" 30" 32.3" 40.5" 3.5" 31.4" 37" 31.4" 31.
Technical drawings - dimensions in inches ≥ 15.8" 3.6" 5.9" 23" 27.4" ≥ 50.4" ≥ 50.4" ≥ 15.8" Installation 13.7" 33.3" 27.
Technical drawings - dimensions in inches PW 814 Dimensions 57.2" 21" 19.4" 29.8" 20" 2.7" 0.9" 22.3" 30.4" 57.1" 16.3" 29.8" 57.1" 36.4" 36.3" 33.5" 36.3" 7.1" 36.4" 1" 4.
Technical drawings - dimensions in inches Dimensions with Miele base (UG/UO)/weighting base (WI) 19.4" 67.3" 2.7" 29.8" 30 32.3" 40.5" 67.2" 21" 16.3" 29.8" 67.2" 36.4" 36.3" 33.5" 36.3" 36.
Technical drawings - dimensions in inches 38.2" 16.2" 32.4" 3.3" 5.8" 24.7" 20.2" ≥ 45.7" ≥ 45.7" ≥ 15.8" ≥ 15.
Technical drawings - dimensions in inches PW 818 Dimensions 57.2" 21" 19.4" 33.8" 20" 2.6" 0.9" 22.3" 30.4" 57.1" 16.3" 33.8" 57.1" 36.4" 36.3" 37.4" 36.3" 36.
Technical drawings - dimensions in inches Dimensions with Miele base (UG/UO)/weighting base (WI) 19.4" 67.3" 2.6" 33.8" 30" 32.3" 40.5" 67.2" 21" 16.3" 33.8" 67.2" 36.4" 36.3" 37.4" 36.3" 36.
Technical drawings - dimensions in inches 38.2" 16.2" 32.3" 3.2" 5.8" 28.6" 24.1" ≥ 49.6" ≥ 49.6" ≥ 15.7" ≥ 15.
Technical drawings - dimensions in inches Anchoring PW 811/814/818 ~ 3 1/2" Attaching to the floor/concrete base Ø 1/2" Dimensions in inches ~ 3 1/2" Attaching to the floor/concrete base when installing in a run Ø 1/2" Dimensions in inches PW 811 / PW 814 / PW 818 25
Technical drawings - dimensions in inches ~ 3 1/2" Attaching to the floor with Miele base Ø 1/2" Dimensions in inches 26 PW 811 / PW 814 / PW 818
Technical drawings - dimension in millimeters PW 811 Dimensions 1352 531 492 795 828 940 472 87 22 529 737 1350 415 827 1350 799 795 164 799 25 86 795 Dimensions in millimeters PW 811 / PW 814 / PW 818 27
Technical drawings - dimension in millimeters Dimensions with Miele base (UG/UO)/weighting base (WI) 827 492 1640 1642 1640 531 415 799 828 762 820 1027 87 795 940 795 799 25 Dimensions in millimeters 28 PW 811 / PW 814 / PW 818
Technical drawings - dimension in millimeters 91 148 697 583 ≥ 1280 ≥ 1280 ≥ 400 ≥ 400 Installation 348 845 696 Dimensions in millimeters PW 811 / PW 814 / PW 818 29
Technical drawings - dimension in millimeters PW 814 Dimensions 1452 531 492 757 507 67 22 564 772 1450 415 757 1450 924 921 850 920 179 924 25 112 Dimensions in millimeters 30 PW 811 / PW 814 / PW 818
Technical drawings - dimension in millimeters Dimensions with Miele base (UG/UO)/weighting base (WI) 1707 531 492 67 758 762 819 1027 1705 415 757 1705 924 920 850 920 924 25 Dimensions in millimeters PW 811 / PW 814 / PW 818 31
Technical drawings - dimension in millimeters 970 411 821 32 82 148 627 513 ≥ 1160 ≥ 1160 ≥ 400 ≥ 400 Installation PW 811 / PW 814 / PW 818
Technical drawings - dimension in millimeters PW 818 Dimensions 1452 531 492 858 507 66 22 564 772 1450 415 857 1450 924 920 950 920 924 25 Dimensions quoted in millimeters PW 811 / PW 814 / PW 818 33
Technical drawings - dimension in millimeters Dimensions with Miele base (UG/UO)/weighting base (WI) 924 1705 1707 531 492 66 858 762 819 1027 1705 415 857 920 950 920 924 25 Dimensions quoted in millimeters 34 PW 811 / PW 814 / PW 818
Technical drawings - dimension in millimeters 970 411 821 PW 811 / PW 814 / PW 818 82 148 727 613 ≥ 1260 ≥ 1260 ≥ 400 ≥ 400 Installation 35
Technical drawings - dimension in millimeters Anchoring PW 811/814/818 ~ 90 Attaching to the floor/concrete base Ø 12 Dimensions in millimeters ~ 90 Attaching to the floor/concrete base when installing in a run Ø 12 Dimensions in millimeters 36 PW 811 / PW 814 / PW 818
Technical drawings - dimension in millimeters ~ 90 Attaching to the floor with Miele base Ø 12 Dimensions in millimeters PW 811 / PW 814 / PW 818 37
Technical data Water connection Models with detergent dispenser drawer (WEK) Permitted supply pressure 14.5-145 psi (1-10 bar) Maximum intake rate 21 gal/min (79.
Technical data Anchoring Attaching to the floor Required anchor points 2 Wood screw (diameter x length) 1/2" x 3 1/2" (12 mm x 90 mm) Wall anchors (diameter x length) 5/8" x 3 1/8" (16 mm x 80 mm) Attaching to the floor with Miele base Required anchor points 4 Wood screw (diameter x length) 1/2" x 3 1/2" (12 mm x 90 mm) Wall anchors (diameter x length) 5/8" x 3 1/8" (16 mm x 80 mm) Attaching to a concrete base (provided on-site) Required anchor points 2 Wood screw (diameter x length) 1/2" x 3
Technical data PW 811 Electrical version and electrical data Electrically heated Standard Connection voltage Frequency Fuse rating (on site) Power rating Rated current Power cord, min. cross-section Cord connector 3 AC 220-240 V 60 Hz 3 x 25 A 10.2-11.8 kW 3 x 23.2 A 4 x AWG 12 M 32 Convertible to: Connection voltage Frequency Fuse rating (on site) Power rating Rated current Power cord, min. cross-section Cord connector 3 AC 200-208 V 60 Hz 3 x 25 A 8.8-9.4 kW 3 x 21.
Technical data Transport data, weight and floor load Packaging width 44.5" (1130 mm) Packaging height 57.8" (1468 mm) Packaging depth 43" (1090 mm) Gross volume 63.9 cu. ft.
Technical data PW 814 Electrical version and electrical data Electrically heated Standard: Connection voltage Frequency Fuse rating (on site) Power rating 3 AC 220-240 V 60 Hz 3 x 40 A 14.8-17.1 kW Rated current 3 x 37.2 A Power cord, min. cross-section 4 x AWG 8 Cord connector M 40 Convertible to: Connection voltage Frequency Fuse rating (on site) Power rating 3 AC 200-208 V 60 Hz 3 x 40 A 12.5 - 13.4 kW Rated current 3 x 32.4 A Power cord, min.
Technical data Installation dimensions Standard Casing width (without add-on components) 36.3" (920 mm) Casing height (without add-on components) 57.1" (1450 mm) Casing depth (without add-on components) 29.8" (757 mm) Overall machine width 36.4" (924 mm) Overall machine height 57.2" (1452 mm) Overall machine depth 33.5" (849,5 mm) Minimum width of transport opening 36.7" (930 mm) Minimum distance between wall and front of appliance 45.
Technical data PW 818 Electrical version and electrical data Electrically heated Standard: Connection voltage Frequency Fuse rating (on site) Power rating Rated current Power cord, min. cross-section Cord connector 3 AC 220-240 V 60 Hz 3 x 50 A 19.4-22.6 kW 3 x 48 A 4 x AWG 8 M 40 Convertible to: Connection voltage Frequency Fuse rating (on site) Power rating 3 AC 200-208 V 60 Hz 3 x 50 A 16.6-17.7 kW Rated current 3 x 41.8 A Power cord, min.
Technical data Installation dimensions Standard Casing width (without add-on components) 36.3" (920 mm) Casing height (without add-on components) 57.1" (1450 mm) Casing depth (without add-on components) 33.8" (857 mm) Overall machine width 36.4" (924 mm) Overall machine height 57.2" (1452 mm) Overall machine depth 37.4" (950 mm) Minimum width of transport opening 36.7" (930 mm) Minimum distance between wall and front of appliance 49.
Please have the model and serial number of your machine available when contacting Technical Service. U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-991-9380 Fax: 609-419-4241 www.miele-pro.com proinfo@mieleusa.com Technical Service & Support Phone: 800-991-9380 Fax: 800-220-1348 proservice@mieleusa.com Alteration rights reserved / Publication date: 0917 PW 811 PW 814 PW 818 M.-Nr.