Installation plan Washer PW 6207 EL en - US 11.11 M.-Nr.
M.-Nr.
Technical Data Sheet Washer: Type of heating: PW 6207 Electric (EL) Legend: Circled, bold-type abbreviations mean: Connection required en - US Abbreviations surrounded by broken circle: Connection optional or required, depending on model Options/Accessories: UM Miele base UO 6020 (UO = open base) Height Width Depth 9 7/16“ 36 1/4“ 39 3/4“ 240 mm 920 mm 1,009 mm UG 6020 (UG = closed-in base) Height Width Depth 9 7/16“ 36 1/4“ 40 1/8“ 240 mm 920 mm 1,019 mm 9 7/16“ 3 15/16“ 36 1/4“ 41 5/16“ 2
The electrical connection may only be made to an electrical system listed in accordance with the national laws, ordinances and directives as well as the local provisions. In addition to this, the regulations of the power supply utility, the accident prevention regulations and the insurance company applicable at the site of installation as well as the recognized standards of technology must also be observed. The installation must be performed by a qualified person (electrician).
Cold water Hard water Water pressure/Min. flow rate Water pressure/Max. flow rate Max. volume flow 14.5 psi 145.04 psi 7 gal/min 100 kPa 1,000 kPa 32 l/min 2 Connector hoses with threaded joint ¾“ including Y fitting (¾“ / 1“) optionally included with the unit. Threaded connector fitting at site as per DIN 44 991 (flat sealing) Length of connector hose 1“ external thread 4„ 11 1/16“ 1“ external thread 1,500 mm 19 gal/h approx. 72 l/h 14.5 psi 145.04 psi 1.45 gal/min 100 kPa 1,000 kPa 5.
Version WI It is essential to ensure that the appliance is fastened adequately to the substrate! Fastening material included with unit: 4 × wood screws DIN 571 (Ø × length) 4 × screw anchors (Ø × length) 1/2” x 3 9/16” 5/8” x 3 1/8” 12 x 90 16 x 80 1/2“ 12 mm Width Depth Height Housing width Housing depth 36 3/8“ 44 1/2“ 55 1/8“ 36 1/4“ 40 3/16“ 924 mm 1,130 mm 1,400 mm 920 mm 1,020 mm Width loading opening (clear width) Recommended wall spacing (to front edge of appliance front) Minimum wall spaci