Programming instructions
32. Free spin speed selection
Selection choice:
–
No
The spin speed programmed into the block
is always used.
–
Yes
The spin set for the last programme block
before starting a programme is used for all
programme blocks. It does not matter if
programme step "Free spin speed
selections" was set to "yes" or "no" in the last
block.
33. Spin
Selection choice:
–
No
Spinning does not take place.
– Automatic
Spin profile
Phase 1 2 3 4 5 6
Time 1min. 1min. 1min. 3min. 3min. 2min.
Rhythm No 12/3 No No No 12/3
Spin speed
(rpm)
500 30 500 850 max. 30
–
User defined
Up to 6 different spin phases can be
programmed for each spin step.
Time 0, 1 to 59 sec
0 to 99 min.
Rhythm No
Normal
Gentle
Gentle+
User defined 3/12 to
(*Total always 015) 99 to 99 sec.*
Spin speed No
Normal
Drench
User defined
20 to 70 rpm.
300 - max. rpm**
**Areas 1 to 19 and 71 to 299 rpm cannot be
selected.
The maximum spin speed available
depends on the machine:
Model Max. spin speed
PW 6101 1200 rpm
PW 6131 1100 rpm
PW 6161 1150 rpm
PW 6201 1100 rpm
PW 6241 1100 rpm
PW 6321 1000 rpm
34. Repeat
A block or programme can be repeated.
Selection choice:
–
No
No repeat.
– Block
Repeat programme blocks
1 x block up to 9 x blocks
– Programme
Repeat programmes
1 x programme up to 9 x programmes
35. Block end signal
If a programme block has finished a signal
can be activated.
Selection choice:
–
No
A block end signal is not given.
–
Yes
The "Block end" output relay is activated.
The block end signal remains active until the
End or Start button or Rotary dial are
activated.
Programming
M.-Nr. 06 533 430 27