Technical data
4.3 Payment system (timed operation)
x
Note
The instructions given in the documentation provided with the payment system
must be followed.
Warning!
The connection has been modified.
Danger of short circuit.
When a time payment system C 5003 is fitted, the connection from pin 7 to
connection 2 on the payment system must be disconnected.
A bridge must be made in the payment system from connection 3 (operational
signal) to connection 2 (transformer).
With incorrect connection, connection from pin 7 to connection 2 on the payment
system not disconnected, a short circuit will exist at the end of the programme.
Check the wiring diagram.
Fig. 4
A Open the pre-punched opening/s in the rear casing for the electrical
connections as necessary.
x
Warning!
Take care to lay wires such that they cannot be damaged by sharp edges.
A Fit the appropriate through-feed parts on the wires. Secure the through-feeds
on the rear casing.
A Lay the payment system wire to the payment system socket (X1/1).
A At the payment system socket (X1/1), cut through the wire bridge 2W14
between pins 3 and 5. Insulate the wire ends.
Descriptive Technical Documentation
090-6 DTD no. 521-7135
This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.2005, DE_en