Technical data
Save and quit
x
Note
Confirmed programmable options are saved.
A Reconnect the fill ring NTC temperature sensor (1R30) plug.
4.2 Programming mode summary
PT 5135 C, PT 5136
Initial requirements
A Finish or cancel any programme in operation, including the demonstration
mode.
A Open the door.
A Disconnect the fill ring NTC temperature sensor (1R30) plug.
x
Note
If the fill ring NTC temperature sensor (1R30) plug is disconnected at the power-
programme module (1N1), then power is also no longer supplied to the door lock
(A2). In this case the programming mode cannot be accessed.
A During initial commissioning only: Select the desired language.
Accessing
x
Note
After it is begun, the accessing procedure must be completed within 10 s.
A Press and hold the Start button.
A Close the door.
A As soon as the Start LED flashes, release the Start button.
A Immediately press and release the Start button 5 times and at the 5th time
hold it pressed in until the Start LED flashes.
Acknowledgement indicator
Successful accessing of the programming mode is indicated by rapid flashing
(5 Hz) of the Start LED.
Descriptive Technical Documentation
DTD no. 521-7135 080-29
14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.