Technical data
3.3 Warning indication: Adjust the load – The drum is empty or the
laundry too dry
Symptom
This warning can only be displayed with residual moisture drying programmes
(i.e. not timed drying).
The programme is cancelled, a cooling phase is started and the buzzer sounds
intermittently.
This warning is cancelled when the door is opened.
Cause
The drum is empty or loaded with a few small items only.
The residual moisture sensing circuit has high resistance and the sensing system
registers no load (no load recognition). This is not a technical fault.
Remedy
A Modify the load or select a timed drying programme.
Cause
Residual moisture sensor (B3/1) defective.
Residual moisture sensor check
A PT 7135 C and PT 7136: Check the residual moisture sensor circuit for low
resistance (continuity), see the ser vice mode Service mode summary, 080
4.5.
A PT 5135 C and PT 5136: Check the residual moisture sensor circuit for low
resistance (continuity), see the ser vice mode Service mode summary,
080 4.6.
A No load recognition, see 080 2.2 No-load recognition.