Operation Manual
Installation
85
Flush-fit installation
Create the worktop cut-out. Remem-
ber to maintain the minimum safety
distances (see “Safety distances”).
Solid wood, tiled and glass worktops:
Fix a wooden frame 5,5mm below
the top edge of the worktop (see
building-in diagram for “Flush-fit in-
stallation”).
Stick the supplied sealing strip under
the edge of the hob.
Feed the mains connection cable for
the hob down through the worktop
cut-out.
Centre the hob in the cut-out.
The gap between the ceramic surface
and the worktop must be at least
2mm wide. This is required so that
the hob can be sealed.
Connect the hob to the mains.
Check that the hob works.
Seal the gap between the hob and
worktop with a silicone sealant that is
heat-resistant to at least 160°C.
Damage from unsuitable sealant.
Unsuitable sealant can damage nat-
ural stone.
For natural stone worktops and nat-
ural stone tiles, only use silicone
sealant that is specially formulated
for natural stone. Follow the manu-
facturer's instructions.