Overheating protection
All the induction coils and cooling ele-
ments for the electronics are fitted with
an overheating protection mechanism.
Before the induction coils and/or cool-
ing elements get too hot, the overheat-
ing protection mechanism cuts in in one
of the following ways:
Induction coils
– Any Booster function in operation will
be switched off.
– The set power level will be reduced.
– The cooking zone turns off automat-
ically. will flash alternately with
in the timer display.
You can use the cooking zone again as
usual when the fault code has gone out.
Cooling elements
– Any Booster function in operation will
be switched off.
– The set power level will be reduced.
– The cooking zones switch off auto-
matically.
The affected cooking zones can only be
used again as usual once the cooling
element has cooled down to a safe
level.
The overheating protection may be ac-
tivated under the following circum-
stances:
– The pan being used is empty.
– Fat or oil being heated on a high
power level.
– Insufficient ventilation to the under-
side of the hob.
– A hot cooking zone being switched
on after an interruption to the power
supply.
If, despite removing the cause, the
overheating protection mechanism trig-
gers again, contact Miele Service.