Technical data
21
Built-under rangehoods
Model DA 2050 DA 2270 DA 2210
Construction type
Built-under rangehood
ššš
Operating modes
Vented operation/Recirculation operation/External operation
š
/
š
/–
š
/
š
/–
š
/
š
/–
User convenience
Rotary selector switch/Joystick
š
/– –/
š
–/
š
Run-on time 5/15 mins. –
šš
Grease filter/Active charcoal filter saturation indicator programmable –/–
š
/
šš
/
š
Easy-to-clean CleanCover hood liner
ššš
Safety switch-off –
šš
Filter system
Dishwasher-proof stainless steel grease filters (10 layers) 1 2 3
Lighting
Halogen/LED
š
/–
š
/–
š
/–
Number x W 2 x 50 W 2 x 50 W 4 x 50 W
Fan
Alternating current motor (AC motor)/Direct current motor (DC motor)
š
/–
š
/–
š
/–
Air throughput with max. duct diameter*
Vented (not with external variants)
In setting 3: Air throughput (m³/h) – 400 1250
Noise power level (dB(A) re 1 pW)/Noise pressure level (dB(A) re 20 μPa)
–/– 53/40 64/51
In Intensive setting: Air throughput (m³/h) 400 640 1850
Noise power level (dB(A) re 1 pW)/Noise pressure level (dB(A) re 20 μPa)
65/52 65/52 77/64
Recirculation
In setting 3: Air throughput (m³/h) – 360 1200
Noise power level (dB(A) re 1 pW)/Noise pressure level (dB(A) re 20 μPa)
–/– 61/48 73/60
In Intensive setting: Air throughput (m³/h) 360 550 1550
Noise power level (dB(A) re 1 pW)/Noise pressure level (dB(A) re 20 μPa)
65/62 70/57 79/66
Technical data
Width/Height/Depth of hood carcase in mm 532/50/372 702/50/402 1102/50/402
Total connected load in kW/Voltage in V 0.19/230 0.30/230 0.78/230
Installation notes
Vent connection top/rear/side
š
/–/–
š
/–/–
š
/–/–
Diameter of vent connection in mm 150 150 150
Accessories supplied
Non-return flap
ššš
Optional extras available at additional charge
Recirculation conversion kit/Active charcoal filter DUU 151/DKF 15-1 DUU 151/DKF 15-1 DUU 151/DKF 15-1
Control module DSM 400/DSM 406 –/–
š
/–
š
/–
Silencer DASD 150/Wall vent DMK 150
š
/
šš
/
šš
/
š