Operating and Installation instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- Installation
- Installation location
- Installation notes
- Specifications for the plumbed water connection
- Installation dimensions
- Dimensions of cabinet fronts
- Building in the appliance
- Before starting...
- Tools required
- Weight of cabinet fronts
- Aligning the installation niche
- Checking the installation niche
- Before installation
- Preparing the installation niche
- Pushing the appliance into the niche
- Aligning the refrigeration appliance
- Securing the appliance in the niche
- Preparing the cabinet fronts
- Securing and aligning the cabinet front
- Mounting the retaining brackets
- Securing the covers
- Installing the cover in a side-by-side combination
- Securing the toe-kick ventilation grille and toe-kick cover
- Limiting the opening angle of the appliance door
- Water connection
- Electrical connection
- Saving energy
- Guide to the appliance
- Accessories
- Before first use
- Switching on and off
- Selecting additional settings
- The correct temperature
- Using Automatic SuperCool and SuperFreeze
- Temperature and door alarm
- Adjusting the interior fittings
- Storing food in the refrigerator section
- Storing food in the MasterFresh zone
- Freezing and storing food
- Making ice cubes
- Automatic defrosting
- Cleaning and care
- Water filter
- Frequently Asked Questions
- Causes of noises
- Customer Service
- Declaration of conformity
- Copyrights and licenses
Installation
*INSTALLATION*
28
Weight of cabinet fronts
Before installing the cabinet fronts,
make sure that they do not exceed the
maximum permitted weight:
Appliance Max.
weight of
upper cabi-
net front
Max.
weight of
lower cabi-
net front
KF2802Vi,
KF2812Vi
99 lb
(45kg)
40 lb
(18kg)
KF2902Vi,
KF2912Vi
88 lb
(40kg)
22 lb
(10kg)
Risk of damage due to excessive
weight of cabinet fronts.
Installing cabinet fronts which are
heavier than the maximum permitted
could damage the hinges.
This damage can affect various fac-
tors, such as operation of the appli-
ance.
Before installing the cabinet fronts,
make sure that they do not exceed
the maximum permitted weight.
Aligning the installation niche
The building-in niche must be carefully
aligned using a spirit level before the re-
frigeration appliance is installed. The
niche corners must be at 90° angles to
each other, otherwise the cabinet front
will not sit straight on all 4corners of
the building-in niche.