Installation Instructions
All Electric Range dimensions
26
HR 1421, HR 1622-2
Position Dimensions Description
 13" (330mm) Maximum depth of top cabinet
 18" (547mm) Minimum distance to bottom edge of top cabinet
 35 1/2"–37"
(901–940mm)
Distance from the floor to cooktop surface
 min. 30"
(762mm)
Niche width
 30" (762mm) Minimum distance between the top of the cooking
area and the bottom of an unprotected
combustible surface.
or 24" (609mm) Minimum distance to a protected combustible
surface or when a Miele Range Hood is installed.
For all other hoods please consult the manufacturer's specifications
for required distances.
 approx.
1013/16" (274m
m)
Maximum connection width right
and left
Position of
the wall
socket
 approx. 4
1/2" (115mm)
Maximum connection height
 approx. 2
13/16" (72mm)
Maximum connection depth
Please observe a safe clearance distance of at least 12" (305mm) from combustible
surfaces located behind the appliance. For zero clearance installation the Miele Backguards
will satisfy the required distance to combustible surfaces. The Miele Backguard is available
in 12"(305mm) or 20"(508mm) heights.